• Contact us
  • Media Centre
  • Software
  • Instruction manuals
  • Blog
Home
/
News
/
Latest Firmware Release for Portable Spectrophotometers

Product Category

Colour MeasurementGloss and Appearance MeasurementLight CabinetsLight and Display MeasurementHyperspectral ImagingVision Quality ControlGraphic Arts

Corporate Information

About usWhere to buyNewsNewsletter subscriptionEvents

Global Information

Corporate InformationCompany OverviewBusiness UnitsSustainabilityInvestor RelationsResearch & Development
Solutions per IndustryService & MaintenanceLearn about Colour & LightDownload Catalogues

Konica Minolta Sensing Europe B.V.

UK United Kingdom - 9 Webster Court, Westbrook Crescent, Gemini Business Park – WA5 8WD Warrington – VAT No. GB883345500

Terms of Use|

Privacy Policy|

Imprint|

|

EU Data Act

©2026 Konica Minolta Sensing Europe B.V.

  • Latest Firmware Release for Portable Spectrophotometers

    Nieuwegein, the Netherlands | 09 Mar 2026

    Enhance the reliability of measurement and evaluation and improve usability in daily operations.

    Firmware_homepage_banner_01

Announcement of the Latest Firmware Release for Portable Spectrophotometers

We are pleased to announce the release of the latest firmware for our portable spectrophotometers.

This update applies to multiple models and is designed to enhance the reliability of measurement and evaluation, as well as to improve usability in daily operations.

Applicable models:

CM‑26dG / CM‑26d / CM‑25d / CM‑17d / CM‑16d / CM‑25cG / CM‑M6

In this update, new functions have been added to support a wider range of measurement needs, including remote colour difference display mode and expanded support for light sources and evaluation indices. In addition, enhancements to user calibration and on‑device display functions make it easier to review and utilise measurement results directly at the instrument.

The firmware also incorporates strengthened security measures, helping to ensure the reliability of measurement data and device management.

Please note that dedicated content is available for the newly added evaluation indices - such as Blackness, Jetness, and Undertone - as well as for the expanded support of CIE LED illuminants. For more details, please refer to the links below.

About the new indices (Blackness / Jetness / Undertone)

Print

See how we are approaching advanced black evaluation and full-spectrum colour measurement for consistent quality control

Learn more

About the additional support for LED illuminants

Print

Read about colour observation and perception and how light shapes the colours we see

Learn more

With these improvements, greater flexibility and usability in colour measurement and evaluation are achieved across a wide range of applications, including research and development, quality control, and on‑site measurement.

For detailed information on supported models and newly added functions, please refer to the table below.

New Functions

CM-26dG

CM-26d

CM-25d

CM-17d

CM-16d

CM-25cG

CM-M6

Ver1.50

Ver1.50

Ver1.20

Ver1.40

Ver1.30

1

Addition of Average Reflectance*¹

✓

✓

✓

-

-

2

Remote Colour Difference Display Mode*²

✓

✓

✓

✓

✓

3

Gloss Diagnosis Result Supported on Main Unit*³

✓

-

-

✓

-

4

Addition of LED Light Sources*⁴

Supported

Supported

Supported

✓

✓

5

Addition of User-Defined Light Sources (3 types)

✓

✓

Supported

✓

✓

6

Addition of Blackness, Jetness and Undertone

✓

✓

Supported

✓

-

7

Manual Input of Colorimetric Data

Supported

Supported

Supported

Supported

✓

8

Expansion of Low-Reflectance Range for User Calibration*⁵

✓

✓

✓

✓

-

   “✓” indicates items newly supported in this update.

*1 Two types of average reflectance: (400–700 nm) and (360–740 nm). CM-25d /17d /16d support only 400–700 nm.

*2 Remote Colour Difference Display Mode enables colour difference measurement results calculated on the instrument to be viewed both in the SpectraMagic NX2 software and on the instrument display.

*3 Supports writing /reading on the main unit; diagnostic results for colour and gloss are displayed separately on the main unit.

*4 CIE LED light sources include 9 types (LED-B1/B2/B3/B4/B5/BH1/RGB1/V1/V2).

*5 Change the setting range for user calibration data to 0.01%–150% (current: 50%–150%).

Share:
  • Konica Minolta Sensing Europe, part of the Industrial Business division of Konica Minolta, Inc. Japan, is a leading provider of measurement solutions for applications in the fields of Colour & Appearance and Light & Display Measurement. Many of Konica Minolta's Measuring Instruments products are used as de facto standards for colour and light measurement. Throughout the EMEA region, Konica Minolta Sensing Europe serves the industry in more than 30 countries with Branch offices and qualified Distributors.

    Derived from our state-of-the-art optical and image processing technologies, measuring solutions from Konica Minolta Sensing help improve quality control and support R&D in a diverse range of industries. We aim to grow Measuring Instruments Business by providing a diverse range of high value-added products solutions that enable high-precision measurement of colour and light. With a commitment to innovation and excellence, we aim to consistently deliver groundbreaking solutions that redefine industry standards. 

    • Our colour & appearance management solutions ensure accurate Quality Control and on-site colour assessments in industries like Automotive, Chemicals, Food, Paints, Plastics, and more.
    • Our light & display management solutions are essential for Quality Assurance to evaluate light sources and display technologies in industries such as Automotive, AR/VR, Consumer Electronics, and Medical Displays.

    Konica Minolta Sensing Europe B.V.

    Marconibaan 57, NL-3439 MR Nieuwegein, The Netherlands

    Tel: +31(0)30 248-1191 / Fax: +31(0)30 248-1280

    Email: Info.Sensing(at)seu.konicaminolta.eu

    Website: https://sensing.konicaminolta.eu/mi-en

    Terms and product names may be trademarks or registered trademarks of their respective holders and are hereby acknowledged.

Contact

Nina Monceaux

European Marketing Manager / Marketing

nina.monceaux(at)seu.konicaminolta.eu

Related Topics

Expanding Global Sensing Solutions

Expanding Global Sensing Solutions

Radiant Vision Systems Merges with Konica Minolta Sensing Americas
Launch Proprietary Computer Colour Matching Software

Launch Proprietary Computer Colour Matching Software

We are launching a new Colour Matching Software this summer!
CL-700A News Release

CL-700A News Release

Konica Minolta to Launch the CL-700A, a New Illuminance Spectrophotometer, as the Next-Generation Solution for Low-Illuminance and High-Speed Measurement Over a Wide Wavelength Range